| A. No, the 400 and 600 terminals come as base units with 4 or 6-inch display, logic module, memory, and power (ac or dc). There are two versions of the base unit; RS-232 only and RS-232 and Ethernet, the latter also supports a network interface for optional communication modules (DH-485, DH+, Remote I/O, ControlNet, and DeviceNet).
|
| A. Yes. It is a drop in replacement for 2-line Dataliners and offers an adapter plate for 4-line Dataliners. See www.ab.com/eoi/inview for detailed application information. |
| A. Downloading to a RS232 (2711-xxx5 or 2711-xxx9) PanelView from the panelbuilder software requires configuring a 1747-PIC driver in RSLinx or Interchange.
The 1747-PIC driver communicates using the DH485 protocol over a RS232 electrical connection. Use one of the following cables to connect the computer communication port to the RS232 PanelView: 2706-NC13, 2711-NC13, 2711-NC14.
The PFT utility can also be used to download to a RS232 (2711-xxx5 or 2711-xxx9)
PanelView from DOS. PanelView File Transfer Utility - 2711-ND7 (version 1.07) Supersedes all previous versions. Allows downloading to all PanelView terminals.
Is available at: http://www.ab.com/mem/technotes/download.html |
| A. InView displays communicate over all major industrial networks.
|
| A. InView Messaging Software programs the entire range of displays in the InView family.
The part number for the software is 2706-PSW1 and the programming cable is 2706-PCABLE1.
|
| A. PanelBuilder32 software is used to program the full family of PanelView Standard terminals.
|
| A. On the PanelView Plus / PanelView Plus CE, go to the Configuration mode, then load the application you want to start automatically. Then make these selections:
- Select "Terminal Settings", then
- Select "Start up Option" then
- Select "Start Current Application". |
| A. Once the IP address has been entered manually on the PanelView Standard it is necessary to restart the terminal for the new settings to take effect.
Once this is done the PanelView Standard will show up on the network and the PING command will complete successfully.
|
| A. The approximate viewing distance’s are
2706-P22R - 7.6m (25 ft)
2706-P43R / 2706-P43C - 60m (200 ft)
2706-P42R / 2706-P42C - 60m (200 ft)
2706-P44R(2), 2706-P44C - 60m (200 ft)
2706-P72CNx / 2706-P74CNx - 100m (350 ft)
2706-P92C / 2706-P94C - 137m (450 ft) |
| A. 3" to 10.5" terminals are available. |
| A. 2711P-RSACDIN -- DIN-rail Mount AC-to-DC Power Supply, 85…265V ac, 47…63 Hz, for PanelView Plus 700-1500 and PanelView Plus CE. |
| A. 9701-VWSTMENE -- FactoryTalk View Studio for Machine Edition is configuration software for developing and testing machine-level human machine interface (HMI) applications. 9701-VWSTENE -- FactoryTalk View Studio for FactoryTalk View is configuration software for developing and testing supervisory-level and machine-level human-machine interface (HMI) applications. |
| A. The standard memory has recently been upgraded from 32Mb flash / 64Mb RAM to 64Mb flash and 64Mb RAM.
|
| A. The 700 to 1500 range is modular and parts such as the screens, memory and Comms modules can be upgraded individually. This form of ordering can often be useful when the lead time on the part is important as there are many possible combinations that will meet your required spec. |
| A. PanelView Standard communicates over all Rockwell Automation networks.
|